COMBIMAX Series

Multi processors for better Accuracy

Multiple microcontrollers’ supervision enables the combimax surgical generators to deliver, control and maintain the power levels dynamically in varying tissue impedances.

Tissue Monitoring technology

Alan’s combimax surgical generator are equipped with tissue monitoring technology. this technology monitors the issue impedance and dynamically varies the HF current & voltage in microseconds to achieve the desired effect on tissue as per selected mode of operation. This prevents unintended power delivery, which helps in faster post recovery of patients as well as protects the instrument from accidental damage due to excessive power/HF voltage.

Smart Auto-start coagulation

Auto-start: In this mode the unit delivers power when tissue is held between forceps or similar instrument by automatically sensing the tissue presence.

Smart auto-stop coagulation

Microcontroller measure the tissue impedance and automatically stops the HF delivery after obtaining “optimum coagulation” Without charring the tissue. Sticking effect & heat produced on instrument is reduced, which increases life of instrument. Thermal spread is also minimized in this mode because the machine senses increase in tissue impedance and stop the delivery at appropriate time.

HF Leakage Monitor & Controller

Active HF leakage Monitor Constantly supervises leakage current. If any current leakage is detected, Microcontroller controls it efficiently. If these current exceeds specified limit, Microcontroller stops the HF delivery and gives Error message with an Audible Alarm

Handswitch and footswitch short detection

Handswitch and Footswitch conditions are scanned during power up self-test. If Handswitch/Footswitch is detected in short/Activated conditions during self-test, it gives an error message with an audible alarm. this prevents the accidental HF power activation during power interruption and also alerts the OT members to check the instrument prior to surgery if a faulty instrument is in use.

199+1 User Programmable profiles

Surgeon can store & recall the complete preferences which includes power setting of each displayed mode, Timeout limit, Footswitch settings, key tone setting, activation tone and volume setting by just selecting program number; by doing this, the total profile is restored. Additionally last activated setting can be restored thus practically 200 profiles are stored.

199+1 User Programmable profiles

  •  Vessel sealing System
  •  Monopolar TUR.
  •  Monopolar.
  •  Bipolar Saline TUR.
  •  Argon Plasma Coagulator
  •  Bipolar.

199+1 User Programmable profiles

  •  Thoracic Surgery
  •  Gynaecology
  •  Liver Surgery.
  •  Laparoscopy & Pelviscopy
  •  TURP, TUVP, TUEB, TCRE etc.

199+1 User Programmable profiles

  •  Gastroenterology.
  •  Carddiac Surgery
  •  Plastic & Reconstructive Surgery
  •  Casualty & General Surgeries
  •  Underwater Surgery
Models Comparision:
DescriptionMBXXXMBAXXMBXVXMBAVXMBXXPMBAXPMBXVPMBAVP
MonopolarPresentPresentPresentPresentPresentPresentPresentPresent
BipolarPresentPresentPresentPresentPresentPresentPresentPresent
APC Present Present Present Present
Vessel Sealer  PresentPresent  PresentPresent
Bi-TUR    PresentPresentPresentPresent
Feature Description
ScalCut mode Precise bipolar tissue cutting
Tissue impedance monitor Real-time safety feedback
Auto-start coagulation Streamlines and improves consistency
Ergonomic design Reduces surgeon fatigue
360-degree rotation Easy maneuverability
Single-instrument use Versatility for entire procedure
Size options 120mm, 150mm, 360mm
Material Stainless steel, EO/gamma sterilizable
Power capacity Up to 400W
Reusability Cost-efficient and sustainable